{"id":2043,"date":"2021-11-26T13:23:19","date_gmt":"2021-11-26T12:23:19","guid":{"rendered":"http:\/\/polysense.poliba.it\/?p=2043"},"modified":"2022-02-08T09:01:51","modified_gmt":"2022-02-08T08:01:51","slug":"new-publication-on-photoacoustics-journal-5","status":"publish","type":"post","link":"https:\/\/polysense.poliba.it\/index.php\/2021\/11\/26\/new-publication-on-photoacoustics-journal-5\/","title":{"rendered":"New Publication on Photoacoustics Journal"},"content":{"rendered":"<p><span style=\"display: inline !important; float: none; background-color: #ffffff; color: #333333; cursor: text; font-family: Georgia,'Times New Roman','Bitstream Charter',Times,serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\">The PolySense team has just published\u00a0 a new article on Photoacoustics Journal Elsevier (IF 8.48)\u00a0 reporting on <\/span>the realization, calibration, and test outdoor of a 19-inches rack sized QEPAS trace gas sensor designed for real-time carbon monoxide monitoring in ambient air. The sensor was tested outdoor in a trafficked urban area for several hours providing results comparable with the daily averages reported by the local air inspection agency, with spikes in CO concentration correlated to the passages of heavy-duty vehicles.<\/p>\n<p>The following link provides access to the article.<\/p>\n<p><a href=\"https:\/\/polysense.poliba.it\/wp-content\/uploads\/2021\/11\/CO-QEPAS-Photoacoustics-2021.pdf\">http:\/\/polysense.poliba.it\/wp-content\/uploads\/2021\/11\/CO-QEPAS-Photoacoustics-2021.pdf<\/a><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-2039\" src=\"https:\/\/polysense.poliba.it\/wp-content\/uploads\/2021\/11\/CO-QEPAS.jpg\" alt=\"\" width=\"1572\" height=\"1170\" srcset=\"https:\/\/polysense.poliba.it\/wp-content\/uploads\/2021\/11\/CO-QEPAS.jpg 1572w, https:\/\/polysense.poliba.it\/wp-content\/uploads\/2021\/11\/CO-QEPAS-300x223.jpg 300w, https:\/\/polysense.poliba.it\/wp-content\/uploads\/2021\/11\/CO-QEPAS-768x572.jpg 768w, https:\/\/polysense.poliba.it\/wp-content\/uploads\/2021\/11\/CO-QEPAS-1024x762.jpg 1024w\" sizes=\"(max-width: 1572px) 100vw, 1572px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The PolySense team has just published\u00a0 a new article on Photoacoustics Journal Elsevier (IF 8.48)\u00a0 reporting on the realization, calibration, and test outdoor of a 19-inches rack sized QEPAS trace gas sensor designed for real-time carbon monoxide monitoring in ambient air. The sensor was tested outdoor in a trafficked urban area for several hours providing <a href=\"https:\/\/polysense.poliba.it\/index.php\/2021\/11\/26\/new-publication-on-photoacoustics-journal-5\/\" rel=\"nofollow\"><span class=\"sr-only\">Leggi di pi\u00f9New Publication on Photoacoustics Journal<\/span>[&hellip;]<\/a><\/p>\n","protected":false},"author":1,"featured_media":973,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2043","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-senza-categoria"],"_links":{"self":[{"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/posts\/2043","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/comments?post=2043"}],"version-history":[{"count":2,"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/posts\/2043\/revisions"}],"predecessor-version":[{"id":2126,"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/posts\/2043\/revisions\/2126"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/media\/973"}],"wp:attachment":[{"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/media?parent=2043"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/categories?post=2043"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/tags?post=2043"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}