{"id":4556,"date":"2026-11-24T16:39:37","date_gmt":"2026-11-24T15:39:37","guid":{"rendered":"https:\/\/polysense.poliba.it\/?p=4556"},"modified":"2026-11-24T16:39:38","modified_gmt":"2026-11-24T15:39:38","slug":"new-publication-on-sensors-and-actuators-b-chemical-journal-10","status":"publish","type":"post","link":"https:\/\/polysense.poliba.it\/index.php\/2026\/11\/24\/new-publication-on-sensors-and-actuators-b-chemical-journal-10\/","title":{"rendered":"New Publication on Sensors and Actuators B Chemical Journal"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The PolySense and Polysense Innovations teams have just published\u00a0 a new article on Sensors and Actuators B Chemical Journal (IF 7.7) reporting on a novel dual-gas quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor based on an<br>\u03b7-shaped dual-resonance acoustic resonator and a low-frequency quartz tuning fork (QTF). The fundamental and overtone modes of the QTF, with resonance frequencies of 2964.4 and 18294.0 Hz, respectively, were employed as two independent frequency channels for simultaneous gas sensing. The \u03b7-shaped resonator was designed to provide acoustic resonance enhancement for both channels. Acetylene (C2H2) and methane (CH4) were selected as the target gases. Compared with the bare-QTF configuration, the second harmonic (2 f) signal amplitudes of C2H2 and CH4 were enhanced by 16.3 and 12.0 times, respectively. Allan deviation\u2011derived minimum detection limits were 148.7 ppb for C2H2 and 155.0 ppb for CH4. Such results confirm that the proposed \u03b7\u2011geometry dual\u2011resonance acoustic resonator constitutes a straightforward and efficient solution for sensitivity enhancement of single\u2011QTF frequency\u2011multiplexed QEPAS sensors in multi\u2011gas analysis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The following link provides access to the article:   <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/polysense.poliba.it\/wp-content\/uploads\/2026\/11\/1-s2.0-S0925400526018241-main.pdf\">https:\/\/polysense.poliba.it\/wp-content\/uploads\/2026\/11\/1-s2.0-S0925400526018241-main.pdf<\/a><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"744\" src=\"https:\/\/polysense.poliba.it\/wp-content\/uploads\/2026\/11\/SNB_Yufei-2026-1024x744.jpg\" alt=\"\" class=\"wp-image-4551\" srcset=\"https:\/\/polysense.poliba.it\/wp-content\/uploads\/2026\/11\/SNB_Yufei-2026-1024x744.jpg 1024w, https:\/\/polysense.poliba.it\/wp-content\/uploads\/2026\/11\/SNB_Yufei-2026-300x218.jpg 300w, https:\/\/polysense.poliba.it\/wp-content\/uploads\/2026\/11\/SNB_Yufei-2026-768x558.jpg 768w, https:\/\/polysense.poliba.it\/wp-content\/uploads\/2026\/11\/SNB_Yufei-2026.jpg 1175w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>The PolySense and Polysense Innovations teams have just published\u00a0 a new article on Sensors and Actuators B Chemical Journal (IF 7.7) reporting on a novel dual-gas quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor based on an\u03b7-shaped dual-resonance acoustic resonator and a low-frequency quartz tuning fork (QTF). The fundamental and overtone modes of the QTF, with resonance frequencies <a href=\"https:\/\/polysense.poliba.it\/index.php\/2026\/11\/24\/new-publication-on-sensors-and-actuators-b-chemical-journal-10\/\" rel=\"nofollow\"><span class=\"sr-only\">Leggi di pi\u00f9New Publication on Sensors and Actuators B Chemical Journal<\/span>[&hellip;]<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-4556","post","type-post","status-publish","format-standard","hentry","category-senza-categoria"],"_links":{"self":[{"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/posts\/4556","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/comments?post=4556"}],"version-history":[{"count":1,"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/posts\/4556\/revisions"}],"predecessor-version":[{"id":4557,"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/posts\/4556\/revisions\/4557"}],"wp:attachment":[{"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/media?parent=4556"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/categories?post=4556"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/polysense.poliba.it\/index.php\/wp-json\/wp\/v2\/tags?post=4556"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}